L’équipe Orchestrator a publié un nouvel article dans la base de connaissances concernant un problème avec l’Orchestrator Runbook service qui démarre puis s’arrête 30 à 60 secondes après. En outre, il enregistre un évènement 7023.
Log Name: System
Source: Service Control Manager
Date:
Event ID: 7036
Task Category: None
Level: Information
Keywords: Classic
User: N/A
Computer: <Computer>
Description:
The Orchestrator Runbook Service service entered the running state.
Log Name: System
Source: Service Control Manager
Date:
Event ID: 7036
Task Category: None
Level: Information
Keywords: Classic
User: N/A
Computer: <Computer>
Description:
The Orchestrator Runbook Service service entered the stopped state.
Log Name: System
Source: Service Control Manager
Date:
Event ID: 7023
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: <Computer>
Description:
The Orchestrator Runbook Service service terminated with the following error:
%%-2147467259
Ce problème survient lorsque le service n’arrive pas à établir une connexion à la base de données. Pour connaître la marche à suivre pour dépanner le problème, rendez-vous sur la KB 2702157 - The Orchestrator Runbook Service starts and then stops after 30-60 seconds